Model No.: GLE-20
Means of Transport: Ocean,Land,Air

Particulate filtration efficiency tester uses aerosol generator to generate a certain concentrat to measure the ion of gas

GLE-20 is an oil-salt two-in-one Face Masks Particulate Filtration Efficiency PFE Tester. According to ASTM F1862-17, ASTM F2299-03 (2017), ASTM F2100-2019, BS EN14683-2019, BS EN 14387-2004+A1 2008, BS EN 136-1998, BS EN 140-1999, BS EN 143-2000 +C1-A1, BS EN 149-2001+A1, etc. It is used to test the particulate filtering efficiency of daily protective masks and medical masks, and to determine the obstruction performance of ordinary fabrics and medical protective masks against a constant flow of airflow. It is widely used for medical device inspection centers, safety protection inspection centers, labor protection inspection centers, drug inspection centers, disease prevention and control centers, textile testing centers, hospitals, mask manufacturers, etc.


Standards:

  • It is designed and manufactured according to YY0469-2004 "Technical Requirements for Medical Surgical Masks" and GB2626-2006 "Respiratory Protective Equipment Self-Suction Filter Anti-Particle Respirator". At the same time, it also refers to the advanced design concepts of similar international equipment (such as the American TSI company), based on the principle of `` European standard EN1822-3: 1998 single-sheet filter material test '', but it is suitable for the test status of domestic related industries

  • GB / T 32610-2016 "Technical Specifications for Daily Protective Masks"

  • GB / T 19082-2009 "Technical requirements for medical disposable protective clothing"

  • GB / T 19083-2010 "Technical Requirements for Medical Protective Masks"

  • GB 24539-2009 General technical requirements for protective clothing and chemical protective clothing

  • YY / T 0969-2013 "Standard for disposable medical masks"

  • Standard Requirement:
    Using sodium chloride particles to detect KN filter elements, and use dioctyl phthalate or equivalent oil particles (or paraffin oil) to detect KP filter elements.
    Test according to 6.3
    During the test, the filtration efficiency of each sample should always meet the requirements of Table 2

    Table 2 Filtration efficiency

    Filter element category and level

    Particle detection with sodium chloride

    Detection with oil particles

    KN90

    90.0%

     

    Not Siut

    KN95

    95.0%

    KN100

    99.97%

    KP90

     

    Not Suit

    90.0%

    KP95

    95.0%

    KP100

    99.97%

    Specifications:

  • Filtration efficiency detection flowmeter range: (10 ~ 100) L / min, accuracy level 2.5

  • Filtration efficiency detection range: (0.001 ~999)%.

  • Filtering efficiency sampling frequency: 1-9999 times / min can be set arbitrarily.

  • Filtration efficiency Particulate concentration: (0.001-200) mg / m³.

  • Differential pressure sensor range: 0 ~1000pa

  • Counting median diameter: salt particles (0.075 ±0.02) μm, oil particles (0.185 ± 0.02) μm. Geometric standard deviation of particle size distribution: salt particles≤1.86, oil particles≤1.60. Dynamic detection range: 0.001-100 mg / m³, accuracy 1%.

  • Test area: 100cm².

  • Aerosol: NaCl (optionally with DOP, DEHS, paraffin oil, corn oil).

  • Aerosol concentration: 12-20mg / m³ (Nacl), 50-200mg / m³ (DOP).

  • The system contains two independent aerosol generators: oily and salty aerosol generators containing two particle counting sensors, one particle concentration sensor and one particle generator

  • Power: AC220V 50Hz(120V/60Hz can be customized)

  • GLE-20 Characteristics:

  • The oil and salt two-in-one test and the two sets of test hardware systems are completely independent. The test does not interfere with each other to ensure the accuracy of the oil and salt test.

  • The aerosol generator is used to produce continuous and stable aerosol particles, which is convenient for filling the solution.

  • A high-precision particle concentration counter (the core component of the sensor imported from the United States) is used to measure the number of aerosol particles.

  • The whole particle anti-leakage design protects the safety of laboratory personnel.

  • Equipped with aerosol particulate static neutralization device.

  • Configure temperature and humidity sensor, real-time display of ambient temperature and humidity (temperature and humidity requirements: 25 ℃ ± 5 ℃, 30% RH ± 10% RH).

  • Equipped with glass rotor flowmeter, vacuum pump and gas electromagnetic flowmeter.

  • Control system: touch-screen computer and test software have been configured to automatically test gas concentration and filtration efficiency, save, output, query, copy and export test data, support A4 paper printing and small bill printing test results

  • Test Report (PDF Report and Result Receipt, can also print in English):


bigPhoto
skype Mr. Jacky Jiang

Tel: 86-21-51083341
Mobile: 139 1846 9858
Contact to this supplier